The Signal Presence component detects the existence of an output signal based on an adjustable Peak Threshold and Hold Time for the peak.
Control |
Function |
Default/Range |
---|---|---|
Input Indicators 1 ton |
The indicator(s) turn green when the input signal reaches the Peak Threshold, and will stay green until the input signal drops below the Peak Threshold, and the Hold Time expires. |
Depends on Properties |
Control |
Function |
Default/Range |
---|---|---|
Peak (dB) |
Sets the peak value of the Input signal that will cause the Input indicator(s) to turn to green. |
Default = -20 Range = -60 to 20 |
Hold time (seconds) |
Sets the time that the indicator(s) will stay green after the peak value of the Input signal drops below the Peak Threshold setting. |
Default = 1.0 Range = 0.01 to 10 |
Infinite Hold |
Causes the Input indicator(s) to stay green, after the peak value of the Input signal reaches the Peak Threshold setting, until the button is released. This is useful when you want to leave the component unattended for a period of time and want to know if the Peak Threshold is reached during that period. |
Off/On |
Property |
Function |
Choices |
---|---|---|
Type |
Sets the Type of Channel available. |
Mono Stereo Multi-Channel |
Count |
Sets the number of Channels available for Multi-channel. |
2 to 256 |
The available Control Pins depend on settings in Properties.
Pin Name |
Value |
String |
Position |
Pins Available |
---|---|---|---|---|
Hold Time |
0.010 to 10 |
10 ms to 10 s |
0.000 to 1.00 |
Input / Output |
Infinite Hold |
0 1 |
false true |
0 1 |
Input / Output |
Peak Threshold |
-60 to 20 |
-60 dB to 20 dB |
0.000 to 1.00 |
Input / Output |
Signal Presence |
0 1 |
false true |
0 1 |
Output |